Shelly Plus 1PM

Device identification

  • Device name: Shelly Plus 1PM
  • Device model: SNSW-001P16EU
  • Device SSID: ShellyPlus1PM-XXXXXX

Short description

Shelly Plus 1PM is a small form factor smart switch with power measurement, which allows remote control of electric appliances through a mobile phone, tablet, PC, or home automation system. It can work standalone in a local Wi-Fi network or it can also be operated through cloud home automation services.

Shelly Plus 1PM can be accessed, controlled and monitored remotely from any place where the user has internet connectivity, as long as the device is connected to a Wi-Fi router and the Internet.

It can be retrofitted into standard electrical wall boxes, behind power sockets and light switches or other places with limited space.

Shelly Plus 1PM has an embedded Web Interface that can be used to monitor and control the device, as well as adjust its settings.

Main applications

  • Residential
  • MDU (Multi Dwelling Units - apartments, condominiums, hotels, etc.)
  • Light commercial (small office buildings, small retail/restaurant/gas station, etc.)
  • Government/municipal
  • University/college

Integrations

  • Google
  • Samsung SmartThings
  • Alexa

Simplified internal schematics

Shelly Plus 1PM internal schematic

Device electrical interfaces

Inputs

  • 1 switch/button input on screw terminal: SW
  • 5 power supply inputs on screw terminals: 2 N (+) and 3 L (Ʇ)

Outputs

  • 1 relay output with power measurement on screw terminal: O

Add-on interface

  • Shelly proprietary serial interface

Shelly Plus 1 addon interface

CAUTION! High voltage on the add-on interface when the device is powered!

Connectivity

  • Wi-Fi
  • Bluetooth

Safety features

  • Overheating protection
  • Overvoltage protection
  • Overcurrent protection
  • Overpower protection

Supported load types

  • Resistive (incandescent bulbs, heating devices)
  • Capacitive (capacitor banks, electronic equipment, motor start capacitors)
  • Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)

User interface

Inputs

  • One (Reset) button
    • Press and hold for 5 seconds to enable device access point and Bluetooth connection.
    • Press and hold for 10 seconds to factory reset the device.

Outputs

  • LED (monocolor) indication
    • AP enabled and Wi-Fi disabled: 1 second ON / 1 second OFF
    • Wi-Fi enabled, but not connected to a Wi-Fi network: 1 second ON / 3 seconds OFF
    • Connected to a Wi-Fi network: Constantly ON
    • Cloud enabled, but not connected: 1 second ON / 5 seconds OFF
    • Connected to Shelly Cloud: Constantly ON
    • OTA (Over the Air Update): ½ sec ON / ½ sec OFF
    • Button pressed and held for 5 seconds: ½ sec ON / ½ sec OFF
    • Button pressed and held for 10 seconds: ¼ sec ON / ¼ sec OFF

The list above starts with the initial device status and the lowest priority. Every next state cancels the previous one.

Specifications

TypeValue
Physical
Size (HxWxD)37x42x16 ±0.5 mm / 1.46x1.65x0.63 ±0.02 in
Weight27 g / 0.95 oz
MountingWall console
Screw terminals max torque0.4 Nm / 3.5 lbin
Conductor cross section0.5 to 1.5 mm² / 20 to 16 AWG
Conductor stripped length5 to 6 mm / 0.20 to 0.24 in
Shell materialPlastic
ColorRed
Environmental
Ambient temperature-20 °C to 40 °C / -5 °F to 105 °F
Humidity30 % to 70 % RH
Max. altitude2000 m / 6562 ft
Electrical
Power supply110 - 240 VAC / 24 - 30 VDC
Power consumption< 1.2 W
Output circuits ratings
Max switching voltage AC240 V
Max switching voltage DC30 V
Max switching current AC16 A
Max switching current DC10 A
Sensors, meters
Internal-temperature sensorYes
Voltmeter (AC)Yes
Ammeter (AC)Yes
Radio
RF band2400 - 2495 MHz
Max. RF power<20 dBm
Wi-Fi protocol802.11 b/g/n
Wi-Fi RangeUp to 30 m / 100 ft indoors and 50 m / 160 ft outdoors
(Depends on local conditions)
Bluetooth Protocol4.2
Bluetooth RangeUp to 10 m / 33 ft indoors and 30 m / 100 ft outdoors
(Depends on local conditions)
MCU
CPUESP32-U4WDH
Flash4 MB
Firmware capabilities
Schedules20
Webhooks (URL actions)20 with 5 URLs per hook
ScriptingYes
MQTTYes
CoAPNo

Basic wiring diagram

110–240 VAC power supply & Resistive load110–240 VAC power supply & Inductive load and RC snubber
Plus 1PM AC wiring diagramPlus 1PM AC RC snubber-wiring
24–30 VDC power supply & Resistive load24–30 VDC power supply & Inductive load and RC snubber
Plus 1pm dc-wiringPlus 1PM DC RC snubber-wiring

Legend

TerminalsDescriptionWiresDescription
OLoad circuit output terminal+24 - 30 VDC positive wire
SWSwitch (controlling O) input terminalNNeutral wire
LLive (110–240 V) terminalGND24 - 30 VDC ground wire
NNeutral terminal
+24 - 30 VDC positive terminal
24 - 30 VDC ground terminal

Troubleshooting

Your device is overheating

  • Make sure you are not using the L and N device terminals as bridges. Using them as bridges doubles the current through them, which leads to overheating. This is only safe with low currents so that the total current does not exceed 16 A.
  • Ensure ambient temperature does not exceed 40 °C / 105 °F. If placed in a confined space, Shelly Plus 1PM may increase the ambient temperature above allowed limits. Ensure proper ventilation.